Certification · Shunde, Foshan

Water Heater Certifications,
Filed as Documents, Not Badges.

Gulfstone builds off-grid outdoor water heaters for importers, RV builders and outdoor brands. A certification is only worth what the buyer can read — so every certificate, letter and laboratory report behind these marks is published in full.

Ask which file applies to your order
Vacuum and pressure gauges on a water heater test bench, needle reading against the dial during the certification test run
The unit on the test bench — instrumentation gauging the certification test run.
File record
Markets
Australia · North America · Europe
Documents
Certificates, letters, reports
Models covered
By configuration
Issued by
AGA · CSA · STS

The file

Three Markets, Three Schemes,
Each Proved by Its Own Document.

Nothing here is one certificate stretched across three regions. Each market has its own scheme, its own standard and its own document, issued by its own body — each previewed below.

AGAAustralia / New Zealand
StandardAS/NZS 2658-2022
DocumentCertificate · issue 01
Issued27 October 2025

LP Gas — portable and mobile appliances. Issued by the Australian Gas Association.

CSA GroupNorth America
StandardCSA/ANSI Z21.96:19 · CSA 11.6:19
DocumentDescriptive report · edition 1
Issued15 July 2025

Class 2781 06 camping equipment (gas) and Class 2781 86, certified to US standards.

Shenzhen STS Test ServicesEurope
StandardLVD 2014/35/EU
DocumentVerification of Conformity
Issued3 December 2024

Battery-operated shower system. The directive covers electrical safety; state the scope when you quote it.

One laboratory served two of these files: the Australian test report was produced by CCIC-CSA International Certification Co., Ltd. in Guangzhou, under the same master contract the North American report carries.

The documents

Read the File,
Not a Summary of It.

Every document behind the table above, shown as it was issued. Reference numbers, the holder entity and the covered models are redacted in these previews.

Australia / New Zealand

AGA Certification File

01

AGA certificate

AGA certificate 9358 page one, listing the certificate holder, the model table and the standard AS/NZS 2658-2022
Issued
27 October 2025
Type
Certificate

The certificate itself: the holder, all 18 covered models, the standard and the gas type.

02

AGA covering letter

AGA covering letter for application 20295, confirming the test results were satisfactory
Issued
27 October 2025
Type
Letter

AGA's own account of the outcome — and the next step: a Product Verification Audit when the first batch is ready.

03

AGA Product Directory entry

The published entry in the AGA Directory of Certified Products, listing each model and its rating
Issued
28 October 2025
Type
Directory

The public Directory entry — the record a buyer or a customs officer can look up independently.

04

Laboratory test report

Draft
Laboratory test report 80247602 cover page from CCIC-CSA International Certification in Guangzhou
5 pp
Issued
Testing 28 Mar – 29 Sep 2025
Type
Report

The evidence under the certificate, from an ISO/IEC 17025-accredited laboratory. Marked Draft on its face — the working report, not a re-issued final.

North America

CSA Certification File

05

CSA descriptive report

Descriptive report 80234452 from CSA Group, covering portable water heaters for outdoor use
11 pp
Issued
15 July 2025
Type
Report

The full report: class designations, the 15 covered models, the model-number breakdown and the alterations record.

Europe

CE Certification File

06

Verification of Conformity

CE Verification of Conformity STS2410092A listing the covered models and the Low Voltage Directive 2014/35/EU
Issued
3 December 2024
Type
Certificate

The declaration of conformity for Europe, naming the directive, the safety standards and all 28 covered models.

07

EUT photographic record

Page one of the laboratory photographic record showing the tested unit, its leads and its accessories laid out against a rule
11 pp
Issued
3 December 2024
Type
Photographs

The unit exactly as the laboratory received it, page by page — the record that ties the certificate to a physical article.

Nothing here is a redrawn summary — each preview is the document as issued, with only the identifying fields masked.

The path

A Certificate Is the Last Step,
Not the First Claim.

The Australian file is followed here from application to marking, because every stage of it is on this page. The other two markets run the same shape through their own bodies.

  1. 01

    Application and Test Programme

    The configuration is submitted and an application number is allocated. AGA set the test programme against the standard before any testing began — for this file, AGA application 20295.

  2. 02

    Independent Laboratory Test

    An accredited laboratory tests the submitted sample against the standard. This file was tested by CCIC-CSA International Certification Co., Ltd. in Guangzhou, accredited to ISO/IEC 17025 under accreditation number TL-464.

  3. 03

    Sample Modification and Re-Test

    Where a test requires a change, the sample is modified and re-run rather than argued past. This file records a modified exhaust outlet and a mesh wind barrier fitted at the bottom before the tests passed.

  4. 04

    Review and Certificate

    The scheme reviews the report and issues the certificate if the results stand. AGA recorded the results as satisfactory with no further assessment required, and issued certificate 9358.

  5. 05

    Production Audit

    The certificate is not the end of the obligation. AGA require a Product Verification Audit — arranged when the first production batch is ready. For this file that audit is outstanding.

  6. 06

    Marking Before Supply

    Nothing ships before the unit carries its marks. AGA require a Maker's Warranty Badge or an AGAMark under licence, plus the Gas Compliance Mark, on every production unit.

The certifying body's condition on the mark

CSA make the certificate conditional on a production test plan run at the factory and documented for their field services representatives. These are CSA's conditions on the mark, not our own line controls — how the line itself is gated is on the quality control page.

  • Burner, manifold and control assembly — proper operationEvery unit
  • Manifold and control assembly — gas tightnessEvery unit
  • Components — regulators, valves, controlsPer batch or per month
  • Burner operating characteristicsPer 1,000 or per week
  • Ignition systems — shut-off within 30 s of flame lossPer 1,000 or per week
  • Combustion — carbon monoxide, air-freePer 1,000 or per week
  • Gas valves and carrying handlesPer 1,000 or per week

Verbatim from the production test plan appended to CSA report 80234452.

Coverage

A Certificate Names Configurations,
Not a Product Line.

Each document lists the model numbers it covers, by suffix that marks the market. What follows is the report's own breakdown of those numbers — the part that says what a suffix means.

18Australia / New Zealandmodels on certificate 9358
15North Americamodels on report 80234452
28Europemodels on verification STS2410092A
Model number breakdownAs printed in CSA descriptive report 80234452.
YN
Trade name YiNuan
JSZ6-SPIH03
Portable water heater with metallic lifting handle
JSZ8-SPIH04
Portable water heater with shoulder belt
JSZ6-SPTIH03
Portable water heater without handle
JSZ6-SPIH03LA
Portable water heater without handle but with lifting belt
LI
On shutdown by overheat, water keeps flowing for 120 s to cool the unit
NB
Without the LI function
LV
Pump button — short press starts water, gas and ignition; long press shifts °C to °F
PV
Pump button — short press starts water, gas and ignition; long press powers the front socket only
Market suffix
-AU
Australia / New ZealandTested to the Australian scheme
-NA
North AmericaTested to the North American scheme
-E…
EuropeTested to the European directive

Certification Attaches to the Configuration That Was Tested

Certification covers the configurations listed above and nothing else. A model outside them is not covered, and a change to a covered one re-opens the file — which is why the alterations record sits below. What applies to your order is confirmed in writing.

Our position on certification claims

The tested configuration

A Live File Records What Changed,
And Closes It.

Certification tests a specific build. When the build changes, the file records the change and the unit is re-tested before the certificate stands — including when a test fails first.

AGA · report 80247602

Sample Modification

The submitted sample was recorded with a modified exhaust outlet and a mesh wind barrier at the bottom — the change the wind test required. The tests were then passed.

Resolved before issue
CSA · report 80234452

Ignition Period

The delayed ignition test failed because the flame flashed out of the appliance. The ignition period was changed from 4 seconds to 1.5 seconds, and the report records the alteration.

Resolved in edition 1

Why We Publish This

Every certification file accumulates notes like these. A file that shows only the passes has been summarised; this one records the change and the fix together, which is the only form in which it is useful to a buyer.

Buyer evidence

What a Complete File Looks Like from the Buyer's Side

From buyers whose compliance lead read the source documents rather than a summary.

“The paperwork arrives with the goods now, instead of after them.”

Two customs clearances, neither held. We import into three markets and every one wants proof before it wants a sample — the first container carried the certificate and the report behind it, so our compliance lead read the source rather than chase us for one.

Sofia MarchettiSourcing Lead at an outdoor equipment importer
“The report listed our exact configuration by name.”

Our model's suffix matched the market it was bound for, so nothing rested on our reading of a range certificate. When we changed the build, the file recorded the change and the paperwork was updated before the next batch shipped.

Nils SørensenProduct Manager at a campervan conversion company

Before you order

The Certificate Questions a Buyer Asks

Which document applies, what is covered, and what the file does not claim.

01Which certificate applies to the unit I order?
It depends on the destination market and the exact configuration. Each document in the file lists the model numbers it covers, and those lists do not overlap across markets — an -AU unit is covered by the Australian certificate and not by the North American one. Tell us the market and the configuration and we will confirm which document applies, in writing, before the order.
02Can I see the certificates before placing an order?
Yes — that is what this page is. Every certificate, letter and laboratory report behind the marks is published as a redacted preview, so your compliance lead can read the source documents rather than take our word for the standard.
03The laboratory report is marked Draft. Is it valid?
It is the working report the certificate was issued on, published as it stands rather than cleaned up. The certificate itself — the document that carries the mark — is the issued version and sits alongside it in the file. We publish the draft because it is the document containing the test detail, and hiding it would make the file less useful.
04Does the European verification cover the gas appliance?
No, and we state that rather than let it be assumed. The European document is a verification of conformity for a battery-operated shower system under the Low Voltage Directive, which covers electrical safety. The directive it names is printed on the document, and it should be read with that scope.
05What happens if you change something on a certified model?
The change is recorded against the certification and the affected tests are re-run before the certificate stands. Our own change-control process — how one approved sample is held as the reference for a whole run — is on the manufacturing page; this page records the changes the certification bodies themselves noted.
06Why is a production audit still outstanding on the Australian file?
Because the certificate is issued before the audit, not after it. AGA require a Product Verification Audit to be arranged when the first production batch is ready, and we would rather publish that than present a complete-looking file. It is the normal sequence, and it will be closed when the first batch runs.

Start a program

The Brief Goes to the Engineer Who Builds It.

Market, annual volume and the certification it must carry — three lines, and we have what we need. Your reply comes from the engineer who would run the line, scoped to your program rather than matched off a shelf.